Observation of Flow Loss on Pneumatic Fly Ash Transport System in Cement Plant
##plugins.themes.academic_pro.article.main##
Abstract
Pneumatic conveying is a material transport tool that utilizes compressed air in a pipe that comes from a blower or compressor. The EP dust raw mill material transport equipment is designed using the pneumatic conveying principle which aims to deliver the material optimally to the cement mill. Therefore, this study aims to analyze the fluid flow in the EP dust Raw Mill material transport system pipe which aims to determine the phenomenon of fluid flow in the pipe design and find the head loss of the material transport pipe. This analysis uses a numerical method that is solving problems by being formulated mathematically by calculating operations and assisted by solidworks software. The size of the pipe to be analyzed is 330 meters long with a diameter of 0.2 meters and has 8 elbows and a head loss of 425.53 meters is obtained, while the results of theoretical calculations obtained a major loss of 374.61 meters and a minor loss of 20.87 meters and the total head loss is 395.48 meters.
Pneumatic conveying merupakan alat transpor material yang memanfaatkan udara bertekanan dalam pipa yang berasal dari blower maupun compressor. Alat transpor material EP dust raw mill dirancang menggunakan prinsip pneumatic conveying yang bertujuan untuk menghantarkan material secara optimal menuju cement mill. Oleh karena itu penelitian ini bertujuan untuk menganalisis aliran fluida yang berada didalam pipa sistem transpor material EP dust Raw Mill yang bertujuan untuk mengetahui fenomena aliran fluida pada desain pipa dan mencari head loss dari pipa transpor material tersebut. Analisis ini menggunakan metode numerik yaitu menyelesaikan permasalahan dengan diformulasikan secara matematis dengan cara operasi hitungan dan dibantu oleh software solidworks. Ukuran Pipa yang akan dianalisis sepanjang 330 meter dengan diameter 0,2 meter dan memiliki elbow sebanyak 8 buah dan didapatkan headloss sebesar 425,53 meter sedangkan dari hasil perhitungan teoritis didapatkan major loss sepanjang 374,61 meter dan minor loss sebesar 20,87 meter dan total head lossnya sebesar 395,48 meter.
##plugins.themes.academic_pro.article.details##

This work is licensed under a Creative Commons Attribution 4.0 International License.
Copyright (c): Muhammad Akhbar, Yolli Fernanda, Refdinal Refdinal, Arwizet K (2022)References
[2] Winarno, “Analisis Kinerja Electrostatic Precipitator (ESP) Berdasarkan Pembagian Besarnya Arus Transformator di PT. PJB UBJOM PLTU Paiton,” J. EECCIS, vol. 14, no. 2, pp. 45–57, 2020.
[3] N. H. T Molek, S. A. Renelda, and S. Syaiful, “Performa cyclone dan electrostatic precipitator sebagai penangkap debu pada pabrik semen,” J. Tek. Kim., vol. 26, no. 1, pp. 22–26, 2020.
[4] A. E. S. Nugroho, “Analisis Kinerja Efisiensi Electrostatic Precipitator Di PLTU Cilacap Unit 1 & 2 ( 2x300MW),” STT PLN, 2017, [Online]. Available: http://156.67.221.169/id/eprint/984
[5] P. N. Wendy, “Perbandingan Analisis Pressure Drop Pada Pipa Lengkung 90 Standart ANSI B36.10 Dengan COSMOSFloworks 2007,” J. Tek. Mesin, 2016.
[6] Nurnawaty and Sumardi, “Analisis perubahan tinggi tekanan akibat sudut belokan 90˚ dan 45˚ dengan menggunakan fluid friction apparatus,” J. Tek. Hidro, vol. 13, no. 1, pp. 28–37, 2020.
[7] A. Felani, “Analisis Statis Konstruksi dan Lance Tube Sootblower Tipe Motorised Rotary Menggunakan Software Solidworks 2016,” 2021. doi: 10.21776/ub.jrm.2021.012.02.1.
[8] T. H. O. Bruce R. Munson, Donald F. young, Mekanika Fluida Jilid 2, Keempat. Erlangga, 2003.
[9] E. A. Pane, I. Ismail, F. D. Yudhanto, and B. Suyitno, “Analisis Penurunan Tekanan Aliran Udara Pada Pipa Bertekanan,” FLYWHEEL J. Tek. Mesin Untirta, vol. 2, no. 2, pp. 13–20, 2019, doi: 10.36055/fwl.v1i1.3111.
[10] C. MULYANA, “Model Pengaruh Diameter Pipa Terhadap Pressure Drop Pada Pipa Pltp Dominasi Uap,” J. Ilmu dan Inov. Fis., vol. 3, no. 1, pp. 26–32, 2019, doi: 10.24198/jiif.v3i1.20624.
[11] G. K. Miyarthaluna and R. Hantoro, “Analisis Pressure Drop pada Jaringan Pipa Pelanggan Biogas di TPA Supiturang Kota Malang,” J. Tek. ITS, vol. 7, no. 1, pp. 1–6, 2018, doi: 10.12962/j23373539.v7i1.27699.
[12] B. Kurniawan, Basuki, and M. A. Irfa’i, “Pengaruh Jenis Sambungan Pipa Elbow 90 ° dan Short Bend Terhadap Head Loss Pada Sistem Perpipaan,” J. Reaktom, vol. 5, no. 1, pp. 28–32, 2020.
[13] S. Dhodapkar, P. Solt, and G. Klinzing, “Understanding bends in pneumatic conveying systems,” Chem. Eng., vol. 116, no. 4, pp. 46–52, 2009.
[14] Philip J. Pritchard, Fluid Mechanics Eighth Edition, Eighth Edi. Macmillan Company, 2011.
[15] T. H. O. Bruce R. Munson, Donald F. young, Fundamental of Fluid Mechanics, Sixth Edit. 2009.